BOSAN

LM-HDS Water-lubricated Screw Air Compressor

Uses water-lubricated compression technology for industrial applications requiring clean air and stable operation.

Request a Quote

Series Reference Configuration

Series Reference Configuration
Working Pressure4–40 bar
Air Delivery (m³/min)0.8–50 m³/min
Configured Power (Combined Motors for Medium Pressure)7.5–405 kW
Local Voltage, Frequency and PhaseCustomized to Your Requirements
Cooling MethodAir-cooled (F) / Water-cooled (S)
Request a Quote
Custom Configuration Available

Voltage, frequency, cooling method and overall compressor configuration can be tailored to your project. For special requirements, contact our sales team for model selection and a quotation.

Series ranges support initial selection, not arbitrary parameter combinations. Contact sales to confirm a specific model and its performance.

Water Lubrication, Sealing and Cooling for Continuous Clean Air

The LM-HDS series uses water to lubricate and seal the compression chamber while removing heat generated during compression. No lubricating oil is injected into the chamber, reducing a source of oil contamination and the associated oil requirement for processes needing oil-free compressed air.

From the Water-lubricated Air End to Local Control

The package combines low-temperature compression, circulating-water filtration and service access. Component and internal views illustrate the design; confirm the supplied configuration for the selected model.

Water-lubricated Single-screw Compression

Clean water provides lubrication, sealing and cooling without oil injection into the compression chamber. Low-temperature compression and low-speed operation support volumetric efficiency and continuous duty. Verify air quality with drying, filtration and point-of-use testing.

Durable Seals and Valves

Seal materials and metal valves combine wear, temperature and corrosion resistance for the circulating-water system. Water quality, valve condition and seal maintenance affect long-term operation; inspect them according to the service schedule.

Local Microcomputer Control

The local interface brings together operating hours, package status and maintenance information for inspection and parameter management. Confirm interface languages, sensors and protective functions for the delivered configuration.

Match Air Supply to Production Demand

Choose a standard-, medium- or low-pressure model for the process, then match load through variable-speed control. Avoid excessive discharge pressure for low-pressure processes; assess savings from measurements under equivalent air-supply conditions.

  1. Air Demand Changes
  2. Drive Adjusts Speed
  3. Air Supply Matches Load

Evaluate Savings for Your Operating Conditions

Compare measured input power before and after an upgrade at equivalent air delivery and pressure. Combine operating hours with the local electricity tariff to calculate the cost difference. Load variation, unloaded hours, pressure settings and existing equipment efficiency all affect the result; a fixed savings percentage cannot replace a site assessment.

Recirculation Filtration and Operating Management

Water is filtered and recirculated through the system. Water quality, temperature and filter condition require routine attention. Monitoring of water temperature, pressure, flow and operating status can support inspections and maintenance. Match the complete configuration to site water conditions, ambient temperature and downstream treatment, including proper care of the water circuit.

Three Pressure Configurations with Complete Model Specifications

Standard-pressure models cover 7.5–315 kW at 8 / 10 bar; low-pressure models cover 11–220 kW at 4 bar. Medium-pressure models operate at 20 / 30 / 40 bar with two motors, up to 220+185 kW. Select by the values in each row; model numbers are not motor-power ratings.

Standard-pressure Models · 8 / 10 bar
ModelPower (kW)Working Pressure (bar)Air Delivery (m³/min)Noise dB(A)Outlet ConnectionWeight (kg)Lubricating Water Volume (L)Filter Element Length × QuantityLength × Width × Height (mm)
LM-HDS7.5F-87.58160RP 3/43002225 cm × 11000 × 720 × 1050
LM-HDS7.5F-107.5100.860RP 3/43002225 cm × 11000 × 720 × 1050
LM-HDS11F-81181.663RP 3/43502225 cm × 11156 × 845 × 1250
LM-HDS11F-1011101.463RP 3/43502225 cm × 11156 × 845 × 1250
LM-HDS15F-81582.565RP 15102850 cm × 11306 × 945 × 1260
LM-HDS18F-8188367RP 16003350 cm × 11520 × 1060 × 1390
LM-HDS18F-1018102.567RP 16003350 cm × 11520 × 1060 × 1390
LM-HDS22F-82283.668RP 16503350 cm × 11520 × 1060 × 1390
LM-HDS22F-1022103.268RP 16503350 cm × 11520 × 1060 × 1390
LM-HDS30F-8308569RP 1 1/48006625 cm × 51760 × 1160 × 1490
LM-HDS30F-1030104.569RP 1 1/48006625 cm × 51760 × 1160 × 1490
LM-HDS37F-83786.271RP 1 1/48506625 cm × 51760 × 1160 × 1490
LM-HDS37F-1037105.871RP 1 1/48506625 cm × 51760 × 1160 × 1490
LM-HDS45S-84587.374RP 1 1/210508825 cm × 51760 × 1160 × 1490
LM-HDS45F-84587.374RP 1 1/412008825 cm × 51760 × 1160 × 1490
LM-HDS8S-84588.174RP 2102011050 cm × 51900 × 1250 × 1361
LM-HDS8F-84588.174RP 2200011050 cm × 52350 × 1250 × 1880
LM-HDS55S-85581074RP 2102011050 cm × 51900 × 1250 × 1361
LM-HDS55S-105510974RP 2102011050 cm × 51900 × 1250 × 1361
LM-HDS55F-85581074RP 2143011050 cm × 72350 × 1250 × 1880
LM-HDS75S-87581375RP 2133011050 cm × 51900 × 1250 × 1361
LM-HDS75S-1075101075RP 2133011050 cm × 51900 × 1250 × 1361
LM-HDS75F-87581375RP 2164011050 cm × 72550 × 1620 × 1880
LM-HDS90S-89081576RP 2126011050 cm × 51990 × 1250 × 1361
LM-HDS90S-10901012.876RP 2126011050 cm × 51990 × 1250 × 1361
LM-HDS90F-89081576RP 2162011050 cm × 72550 × 1620 × 1880
LM-HDS110S-811082078DN 65179013050 cm × 122200 × 1600 × 1735
LM-HDS110S-101101017.878DN 65179013050 cm × 122200 × 1600 × 1735
LM-HDS110F-811082078DN 65350013050 cm × 123000 × 1700 × 2250
LM-HDS132S-813282380DN 65207013050 cm × 122200 × 1600 × 1735
LM-HDS132S-10132101980DN 65207013050 cm × 122200 × 1600 × 1735
LM-HDS160S-816082682DN 65290016550 cm × 122200 × 1600 × 1735
LM-HDS185S-818583083DN 100330018050 cm × 222860 × 1800 × 1945
LM-HDS200S-820083383DN 100350018050 cm × 222860 × 1800 × 1945
LM-HDS220S-822083685DN 100450018050 cm × 222860 × 2000 × 2300
LM-HDS250S-825084085DN 100470018050 cm × 222860 × 2000 × 2300
LM-HDS315S-831585090DN 100500018050 cm × 222860 × 2000 × 2300
Medium-pressure Models · 20 / 30 / 40 bar
ModelPower (kW)Working Pressure (bar)Air Delivery (m³/min)Noise dB(A)Outlet ConnectionWeight (kg)Length × Width × Height (mm)
LM-HDS52ZF-6.0/2.037+1520670DN 2518203000 × 1400 × 1700
LM-HDS52ZS-6.0/2.037+1520670DN 2514002900 × 1400 × 1700
LM-HDS59ZF-6.0/3.037+2230670DN 2520003000 × 1400 × 1700
LM-HDS59ZS-6.0/3.037+2230670DN 2517002900 × 1400 × 1700
LM-HDS67ZF-6.0/4.037+3040670DN 2521003000 × 1400 × 1700
LM-HDS67ZS-6.0/4.037+3040670DN 2518002900 × 1400 × 1700
LM-HDS77ZF-10.0/2.055+22201073DN 3230003600 × 1750 × 2000
LM-HDS77ZS-10.0/2.055+22201073DN 3222003500 × 1500 × 1730
LM-HDS92ZF-10.0/3.055+37301073DN 3230003600 × 1750 × 2000
LM-HDS92ZS-10.0/3.055+37301073DN 3223003500 × 1500 × 1730
LM-HDS112ZF-10.0/4.075+37401073DN 3234004000 × 1750 × 2030
LM-HDS112ZS-10.0/4.075+37401073DN 3224003500 × 1500 × 1730
LM-HDS105ZF-13.0/2.075+30201375DN 4035004000 × 1750 × 2030
LM-HDS105ZS-13.0/2.075+30201375DN 4027003500 × 1500 × 1730
LM-HDS120ZF-13.0/3.075+45301375DN 4035004000 × 1750 × 2030
LM-HDS120ZS-13.0/3.075+45301375DN 4029503500 × 1500 × 1730
LM-HDS135ZS-13.0/4.090+45401375DN 4030003500 × 1500 × 1730
LM-HDS127ZS-16.0/2.090+37201677DN 4033004000 × 1700 × 1800
LM-HDS145ZS-16.0/3.090+55301677DN 4035004000 × 1700 × 1800
LM-HDS165ZS-16.0/4.0110+55401677DN 4035004000 × 1700 × 1800
LM-HDS165ZS-20.0/2.0110+55202078DN 5036504000 × 1700 × 1800
LM-HDS185ZS-20.0/3.0110+75302078DN 4040004000 × 1700 × 1800
LM-HDS207ZS-20.0/4.0132+75402078DN 4040004000 × 1700 × 1800
LM-HDS197ZS-24.0/2.0132+65202478DN 5045004000 × 1800 × 2100
LM-HDS222ZS-24.0/3.0132+90302478DN 5045004000 × 1800 × 2100
LM-HDS250ZS-24.0/4.0160+90402478DN 5046004000 × 1800 × 2100
LM-HDS220ZS-28.0/2.0185+55202878DN 6546004200 × 2000 × 2100
LM-HDS260ZS-28.0/3.0185+75302878DN 5047004200 × 2000 × 2100
LM-HDS290ZS-28.0/4.0200+90402878DN 5048004200 × 2000 × 2100
LM-HDS295ZS-36.0/2.0185+110203680DN 6550004500 × 2250 × 2200
LM-HDS317ZS-36.0/3.0185+132303680DN 6550004500 × 2250 × 2200
LM-HDS360ZS-36.0/4.0200+160403680DN 6550004500 × 2250 × 2200
LM-HDS1330ZS-40.0/2.0220+110204080DN 6550004500 × 2250 × 2200
LM-HDS325ZS-40.0/3.0220+132304080DN 6550004500 × 2250 × 2200
LM-HDS405ZS-40.0/4.0220+185404080DN 6550004500 × 2250 × 2200
Low-pressure Models · 4 bar
ModelPower (kW)Working Pressure (bar)Air Delivery (m³/min)Noise dB(A)Outlet ConnectionWeight (kg)Length × Width × Height (mm)
LM-HDS15DF-41142.558RP 16001306 × 945 × 1260
LM-HDS22DF-41543.660RP 18001520 × 1060 × 1390
LM-HDS37DF-4224561RP 1 1/410501760 × 1160 × 1490
LM-HDS45DF-43748.165RP 219502350 × 1250 × 1880
LM-HDS45DS-43748.165RP 211501900 × 1250 × 1361
LM-HDS55DF-44541070RP 220502350 × 1250 × 1880
LM-HDS55DS-44541070RP 212001900 × 1250 × 1361
LM-HDS75DF-45541371RP 224002550 × 1620 × 1880
LM-HDS75DS-45541371RP 215501900 × 1250 × 1361
LM-HDS90DF-47541575RP 225502550 × 1620 × 1880
LM-HDS90DS-47541575RP 220001900 × 1250 × 1361
LM-HDS110DF-49042077DN 6533503000 × 1700 × 2250
LM-HDS110DS-49042077DN 6525502200 × 1600 × 1735
LM-HDS160DS-411042677DN 6527502200 × 1600 × 1735
LM-HDS185DS-413243078DN 10031002860 × 1800 × 1945
LM-HDS200DS-416043378DN 10033002860 × 1800 × 1945
LM-HDS250DS-418544079DN 10044002860 × 1800 × 1945
LM-HDS315DS-420044580DN 10045002860 × 1800 × 1945
LM-HDS355DS-422045080DN 10046002860 × 1800 × 1945

F denotes air cooling and S water cooling; confirm cooling requirements for the selected model. Medium-pressure power is listed separately for two motors, for example 220+185 kW, not a single-motor rating. Air delivery applies at the pressure in each row. Confirm voltage, frequency, phases and final model codes before ordering.

Flow reference conditions: 0.1 MPa absolute inlet pressure, 20°C inlet temperature and 0% relative humidity, per JB/T11882-2014. Lubricating water volume is not hourly water consumption. Select filter quantity, dimensions and weight for the corresponding model.

Buying Questions

What information is needed for selection?

Product matching based on equipment brand, model, power, pressure, installation dimensions and operating conditions.

How are performance and configuration confirmed?

This page provides an initial product overview. The final model, performance data and configuration must be confirmed against official technical documents and the customer's actual operating conditions.

How are lead time and warranty confirmed?

Technical documents, applicable compliance scope, production schedule and warranty terms are confirmed for the selected model, configuration and destination market during quotation.

How can I request a quotation?

Briefly describe what you need and leave either an email address or another contact method. Our team will review your request and reply promptly.

Request a Quote