BESY Compact Mobile Integrated Screw Air Compressor
Integrated compression and air storage for service workshops and small equipment installations.
Request a QuoteSeries Reference Configuration
| Working Pressure | 8 / 10 / 13 bar |
|---|---|
| Air Delivery (m³/min) | 0.38–2.25 m³/min |
| Motor Power | 3–15 kW |
| Local Voltage, Frequency and Phase | 220 V single-phase / three-phase; 380 V three-phase; 50 / 60 Hz |
| Cooling Method | Air-cooled |
Custom Configuration Available
Voltage, frequency, cooling method and overall compressor configuration can be tailored to your project. For special requirements, contact our sales team for model selection and a quotation.
Series ranges support initial selection, not arbitrary parameter combinations. Contact sales to confirm a specific model and its performance.
Integrated Compression and Storage for Flexible Small-scale Production
The screw air end, motor, controls and receiver share one platform, reducing separate storage equipment and external piping for machinery integration, service workshops and small production sites. The compact layout supports flexible placement, with mobility arrangements selected for relocation and site requirements.
Ten Design Features for Air Supply and Servicing
The air end, motor, filtration, controls and storage share one platform. The drawing illustrates the main components; confirm the appearance, controls and accessories for the selected configuration.
Low-speed, High-torque Air End
The screw air end balances air delivery, noise and operating stability. Select it for sustained air consumption and required pressure, not motor power alone.
Multi-layer Pleated Oil Filter
Pleated media increases effective filtration area, balancing dirt-holding capacity, low resistance and easy replacement. Confirm filter rating and replacement intervals for the model and contamination level.
IP23 Copper-wound Motor Configuration
The copper-wound motor balances starting torque and efficiency. Install the IP23 configuration in a suitably protected environment. It is not a dustproof, waterproof or explosion-proof package; confirm suitability for damp or dusty sites in advance.
Full-flow Inlet Filtration
The inlet filter and valve are matched to air-end flow to reduce unnecessary intake pressure loss. Inspect the filter regularly and keep the intake path clean and clear.
Variable-speed Configuration for Demand-based Output
The PM variable-speed version adjusts speed to demand to reduce unloaded power consumption. The fixed-speed version uses contactor direct starting. Air delivery, weight and starting method are listed separately for each configuration.
Minimum-pressure Valve
Establishes and maintains the minimum internal pressure required by the package and helps prevent reverse flow. The compact valve supports integration and should be inspected according to service instructions.
Visible Oil-level Indication
Upper and lower oil-level marks simplify routine checks and help identify abnormal levels. Follow the equipment instructions for checking conditions and oil replenishment.
Separate Oil and Discharge Pressure Indication
A dual-gauge configuration provides separate oil and discharge pressure readings for a clear operating overview. Confirm gauge units and the supplied arrangement for the selected model.
Caster Wheels for Convenient Relocation
Wheel options include metal and low-noise types to suit load, wear and mobility needs. Stop, isolate power and depressurize as instructed before moving. Secure the package on level ground during operation.
Enlarged Cooler and Guided Airflow
An enlarged heat-transfer area and a suction fan with an airflow shroud help remove heat continuously. Allow ventilation and cleaning access for cooler and fan maintenance.
Match Air Supply to Production Demand
Fixed-speed and variable-speed configurations suit different load profiles. For varying demand, PM variable-speed control can adjust speed as needed. For steady loads, compare measured energy consumption and purchase cost for the relevant models.
- Air Demand Changes
- Drive Adjusts Speed
- Air Supply Matches Load
Evaluate Savings for Your Operating Conditions
Compare measured input power before and after an upgrade at equivalent air delivery and pressure. Combine operating hours with the local electricity tariff to calculate the cost difference. Load variation, unloaded hours, pressure settings and existing equipment efficiency all affect the result; a fixed savings percentage cannot replace a site assessment.
Complete Fixed-speed and PM Variable-speed Configuration Comparison
Match the supply phase, power, target pressure and air demand. The two tables list every configuration separately, without treating different phases or starting methods as interchangeable.
| Parameter / Configuration Model | JGM4/S | JGM5.5/S | JGM7.5/S | JGM10/S | JGM4 | JGM5.5 | JGM7.5 | JGM10 | JGM20 |
|---|---|---|---|---|---|---|---|---|---|
| Power (kW / HP) | 3 / 4 | 4 / 5.5 | 5.5 / 7.5 | 7.5 / 10 | 3 / 4 | 4 / 5.5 | 5.5 / 7.5 | 7.5 / 10 | 15 / 20 |
| Air Delivery at 7 bar (m³/min) | 0.41 | 0.49 | 0.90 | 1.07 | 0.41 | 0.49 | 0.90 | 1.07 | 2.25 |
| Air Delivery at 10 bar (m³/min) | 0.38 | 0.46 | 0.88 | 1.02 | 0.38 | 0.46 | 0.88 | 1.02 | 1.85 |
| Working Pressure (bar) | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 |
| Motor Speed (rpm) | 2960 | 2960 | 2960 | 2960 | 2960 | 2960 | 2960 | 2960 | 2960 |
| Voltage and Phase | 220 V / single-phase; 220 V / three-phase | 220 V / single-phase; 220 V / three-phase | 220 V / single-phase; 220 V / three-phase | 220 V / single-phase; 220 V / three-phase | 220 V / single-phase; 220 V / three-phase | 380 V / three-phase | 380 V / three-phase | 380 V / three-phase | 380 V / three-phase |
| Frequency (Hz) | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 |
| Cooling Method | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled |
| Starting Method | Contactor Direct Starting | Contactor Direct Starting | Contactor Direct Starting | Contactor Direct Starting | Contactor Direct Starting | Contactor Direct Starting | Contactor Direct Starting | Contactor Direct Starting | Contactor Direct Starting |
| Outlet Size (DN) | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 |
| Weight (kg) | 108 | 120 | 125 | 127 | 110 | 122 | 127 | 130 | 231 |
| Dimensions (mm) | 900 × 450 × 880 | 1000 × 500 × 1050 | 1000 × 500 × 1050 | 1000 × 500 × 1050 | 900 × 450 × 880 | 1000 × 500 × 1050 | 1000 × 500 × 1050 | 1000 × 500 × 1050 | 1080 × 750 × 1000 |
| Parameter / Configuration Model | JGM4VS | JGM5.5VS | JGM7.5VS | JGM10VS | JGM4V | JGM5.5V | JGM7.5V | JGM10V | JGM20 |
|---|---|---|---|---|---|---|---|---|---|
| Power (kW / HP) | 3 / 4 | 4 / 5.5 | 5.5 / 7.5 | 7.5 / 10 | 3 / 4 | 4 / 5.5 | 5.5 / 7.5 | 7.5 / 10 | 15 / 20 |
| Air Delivery at 7 bar (m³/min) | 0.56 | 0.63 | 1.07 | 1.31 | 0.56 | 0.63 | 1.07 | 1.31 | 2.25 |
| Air Delivery at 10 bar (m³/min) | 0.49 | 0.50 | 0.92 | 1.02 | 0.49 | 0.50 | 0.92 | 1.02 | 1.85 |
| Working Pressure (bar) | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 | 8 / 10 / 13 |
| Motor Speed (rpm) | 1500–3600 | 1500–3600 | 1500–3600 | 1500–3600 | 1500–3600 | 1500–3600 | 1500–3600 | 1500–3600 | 1500–3600 |
| Voltage and Phase | 220 V / single-phase; 220 V / three-phase | 220 V / single-phase; 220 V / three-phase | 220 V / single-phase; 220 V / three-phase | 220 V / single-phase; 220 V / three-phase | 380 V / three-phase | 380 V / three-phase | 380 V / three-phase | 380 V / three-phase | 380 V / three-phase |
| Frequency (Hz) | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 |
| Cooling Method | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled |
| Starting Method | Variable-speed Starting | Variable-speed Starting | Variable-speed Starting | Variable-speed Starting | Variable-speed Starting | Variable-speed Starting | Variable-speed Starting | Variable-speed Starting | Variable-speed Starting |
| Outlet Size (DN) | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 |
| Weight (kg) | 110 | 125 | 128 | 130 | 110 | 125 | 128 | 130 | 231 |
| Dimensions (mm) | 900 × 450 × 880 | 1000 × 500 × 1050 | 1000 × 500 × 1050 | 1000 × 500 × 1050 | 900 × 450 × 880 | 1000 × 500 × 1050 | 1000 × 500 × 1050 | 1000 × 500 × 1050 | 1670 × 630 × 1450 |
Air-delivery values apply at 7 bar and 10 bar, not at 8 bar or 13 bar. Confirm the power-supply combination, pressure version and final configuration before ordering; request 13 bar air delivery separately. Configuration codes distinguish the listed specifications; the supplied package follows the BOSAN proposal.
Small-scale Air Supply Matched to the Process
- Metalworking and Pressure Forming
- Precision Machinery, Electronics and Packaging
- Spraying and Lithium-battery Equipment
- Auxiliary Air for Food and Pharmaceutical Equipment
- Cleaning, Stamping and Small-scale Sandblasting
- Engineering, Power and Field Maintenance
These are potential integration uses, not a claim that a compact package can supply an entire plant. Spraying, food and pharmaceutical processes require separate confirmation of pressure, air quality, drying and filtration. This is not breathing-air equipment.
Buying Questions
What information is needed for selection?
Product matching based on equipment brand, model, power, pressure, installation dimensions and operating conditions.
How are performance and configuration confirmed?
This page provides an initial product overview. The final model, performance data and configuration must be confirmed against official technical documents and the customer's actual operating conditions.
How are lead time and warranty confirmed?
Technical documents, applicable compliance scope, production schedule and warranty terms are confirmed for the selected model, configuration and destination market during quotation.
How can I request a quotation?
Briefly describe what you need and leave either an email address or another contact method. Our team will review your request and reply promptly.